Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13776420
![](http://i.b2b168.com/e/tag_pthy.gif)
- Product Categories
- Friendly Links
Information Name: | Basement fresh air units | Keao Environment | Wuxi basement ceiling fresh air unit |
Published: | 2015-07-07 |
Validity: | 0 |
Specifications: | Any |
Quantity: | |
Price Description: | |
Detailed Product Description: | Capillary network of fresh air dehumidification unit Features 1, especially for capillary network air system to dehumidify Wuxi basement fresh air unit manufacturers, solve the case capillary network system condensation Wuxi basement fresh air units dehumidify and may introduce fresh air, the capillary network system really work its energy-saving, mute features. Relieve worries condensation 2, intelligent design intelligent humidity control can dehumidification, humidification can be. Multi-stage automatic control dehumidification process. Winter wind at the same time introducing new, automatic reheat multiple protection design. 3, professional design according to the characteristics of the capillary network, especially for comfort, anti-condensation, installation location, height Wuxi basement purchase new air unit, the air moisture content, temperature and other parameters, professional design, fully meet customer requirements 4 , energy efficient multi-polar condensing mode up to three levels automatically adjusted according to state of the environment. Highly efficient energy-saving new wind unit cooler winter deactivated in standing water in the basement of the new air unit deactivated after the winter frost crack cooler accident occurred, mainly due to air in the new unit has a standing water cooler. Possible reasons are as follows: (a) run cooler not open sluice valve, so that no cooler air into the channel, so the water inside the cooler can not be completely emptying, resulting in reduced winter outdoor temperatures after new wind unit cooler cracking. (B) due to a cold water system piping water in the basement of the new air unit, bit Ge new air handling units and lower than the main pipe system, if the connection line valves closed lax, water in the cold water supply and return water pipeline begins slowly seep into the table Cooler, so despite the draining operation will still lead to the cracking of the accident. The accident may be the two reasons, one cause, and therefore both areas improved, adding DN15 discharge pipe at the highest point of the supply and return risers new air handling units, air handling units in the new deflated and draining when they can be used, in particular, to ensure the thoroughness of the discharge; and in the fresh air supply and return water on the road of establishing an additional valve unit, completely cut off slow down bleeding problems after discharge. Basement fresh air units | Keao Environment | Wuxi basement ceiling fresh air unit provided by the Nanjing Environmental Engineering Equipment Co., Ltd. Keao. Basement fresh air units | Keao Environment | Wuxi basement ceiling fresh air unit is Keao Nanjing Environmental Engineering Equipment Co., Ltd. (www.njxfxt.com) this year introduced a new upgrade, the above picture is for reference only, please call or pictures on this page contact telephone number, to obtain the latest information, contact: Li. |
Admin>>>
You are the 31058 visitor
Copyright © GuangDong ICP No. 10089450, Keao Nanjing Environmental Engineering Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 31058 visitor
Copyright © GuangDong ICP No. 10089450, Keao Nanjing Environmental Engineering Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility